Astrapool Dual Pure 160 매뉴얼 - 페이지 12

{카테고리_이름} Astrapool Dual Pure 160에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Astrapool Dual Pure 160 20 페이지. Salt electrolysis and ph regulation

ADJUSTING THE DURATION OF THE POLARITY INVERSION

Your salt chlorinator was programmed in the factory for a polarity change every 4 hours.
According to the hardness of the water (TH for degree of Total Hardness), it is possible to change this
cycle from 1 to 99 hours.
Switch off the device
-
Press
and
-
Keep
and
-
Press Menu, DUR appears.
-
Press Menu, the duration of the polarity inversion is displayed; press
value.
-
Press Menu to confirm
SELF TEST:
Warning! Water temperature > 23°C, minimum salt content 4g/l.
This function allows one to check the state of the electrode and that the unit is working properly.
Press the "TEST" key.
The LEDs light up,
Then "prod 1" followed by "prod2".
If all of the LEDs flicker after 30 seconds, then the test is OK.

CHECKS AND MAINTENANCE

CHECK THE PARAMETERS:
Press "MENU" for two seconds,
Scroll through the functions using
Then press "Menu" to visualise:
-
DUR duration of the polarity inversion (self-cleaning expressed in hours).
Factory setting: 4
-
FE: regulates production according to the position of the cover.
Percentage of production depends on the cover being in the closed position.
Factory setting: 50%
-
INT: intensity sent to the electrode (expressed in amperes).
simultaneously while switching on the device.
pressed until the screen displays ATT then PRO.
or
,
12
Número de revisión
ENGLISH
or
to change the
Rev 001-2013-08-06