Air Fantastic CAP5000 소유자 매뉴얼 - 페이지 9

{카테고리_이름} Air Fantastic CAP5000에 대한 소유자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Air Fantastic CAP5000 16 페이지. Central air purifier (cap)

Preparing to Install Your New CAP System
The CAP System was designed to be simple and effective. Remove the unit,
power adapter, power cord, mounting hardware (eight self tapping screws) from
the box. We recommend keeping the box and all packaging material for shipping
the unit should it ever need to be returned for repairs.

Installation Instructions

Installation and servicing of air-conditioning equipment can be hazardous due to
system pressure and electrical components. Only trained and qualified service
personnel should install, repair, or service air-conditioning equipment. Air Fan-
tastic and its affiliates are not responsible for any damage to the HVAC system,
CAP System or injury to yourself or others if you elect to install the device without
utilizing qualified technicians.
Use the suggestions on page 6 to determine the optimal mounting location(s).
To complete the installation process you will need the following tools:
Power Drill
4 inch hole saw
1/4 inch hex head screw driver
1.
Using the steps on page 6, determine the optimal mounting location of your
new CAP System. The mounting location should be within 10 feet of an elec-
trical outlet.
2.
Thoroughly clean and dry at least a 12" X 12" area at the location where
the CAP System will be mounted. If available, clean with rubbing alcohol &
paper towel for a better adhesive seal to the duct. Be sure rubbing alcohol
dries completely. Using a 4" inch hole saw, cut a 4" hole in the duct where the
device will be mounted. Center the hole ensuring there will be at least a 5"
diameter of duct around the outside of the hole.
4"
5"
7