Astrel MICROSPA 설치 및 사용자 설명서 - 페이지 4
{카테고리_이름} Astrel MICROSPA에 대한 설치 및 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Astrel MICROSPA 7 페이지.
10. Starting for the first time
Before switching the controller on for the first time, make sure that:
•
there is sufficient water in the pool;
•
all the valves are open;
•
there is nothing that can block the flow of the water in the pipes.
Moreover, check that the connections of the loads correspond to the configuration settings.
Generally, when starting for the first time, the temperature of the water introduced into the spa should be lower
than the temperature set point (35° C). For this rea son, when started, the controller will activate the pump to
send the water to the heater, as well as the heater itself.
11. Main functions
This section describes the most commonly used functions during the operation of the controller.
• Pump1
The first press the pump is active in low speed and the led blinking (*)
The second press the pump is active in high speed and the led is on solid.
The third press the pump is off.
If the pump is not stopped manually, it stops automatically after 20 minutes of operation.
(*) Only if set for duel speed in low-level programming.
• Pump2 or Blower (*)
The first press the pump or the blower is active in high speed and the led is on solid
The second press the pump or the blower is off.
If the pump or blower is not stopped manually, it stops automatically after 20 minutes of operation.
(*) Only if set as blower or pump in low-level programming.
• Light
The first press the light is turned on high intensity and the led is on solid.
The second press the light is turned on low intensity and the led blinking.
The third press the light is turned off.
If the light is not turned off stopped manually, it stops automatically after 20 minutes of operation.
• Controlling the water temperature (Up/Down arrow)
The MICROSPA controller can control water temperature in a range of temperatures between 15 and 40° C.
The user can set the desired temperature from keypads using on the UP/DOWN key.
The temperature control function is achieved by heating the water using the heater connected to the
controller. When the water temperature is less than the desired temperature, the MICROSPA controller:
•
starts the pump configured as the heating pump
•
checks the flow of water through the heater, using the pressure switch (this takes a few seconds);
•
starts the heater.
Once the set point has been reached, the MICROSPA controller first deactivates the heater and, after 1
minute, the pump to avoid overheating the heating element.
The water is cooled by simply not activating the heater. The water may not cool down when the ambient
temperature is high.
D:\LAVORO\CONTROLLI SPAS\MANUALI INSTALLAZIONE\MICROSPA\Instruction Microspa.doc
Astrel S.p.A.
Via Isonzo, 21/E – 34070 Mossa (GO) Italy
Tel. (+39) 0481 637301 r.a.-Fax (+39) 0481 637362
e-mail: [email protected] – www.astrel.it
Cap. Soc. € 619200. i.v.
Tribunale di Gorizia n. 3505
R.E.A. n. 049936 – M/351122
Part. IVA e Cod. Fisc. 00187070313
Sheet 4/7