Doosan HM 5000 Atc 문제 해결 - 페이지 14

{카테고리_이름} Doosan HM 5000에 대한 Atc 문제 해결을 온라인으로 검색하거나 PDF를 다운로드하세요. Doosan HM 5000 16 페이지.

Doosan HM 5000 Atc 문제 해결
HM 5000/6300/8000
◈ Tool Re-Charge Step Sequence Chart
M06 End
1
Waiting Pot Magazine Side
Waiting Pot
Spindle Side?
Yes
2
Sub Changer Wait. Pot Position
Sub Changer
Waiting Pot Pos.?
Yes
Sub Changer Arm Out
3
Sub Changer Arm
Out O.K?
Yes
4
Sub Changer Mag. Pot Position
Sub Changer Pot
Position?
Yes
Go to "A"
12
Output: Y2.7(WPMS.R) –YV30 Waiting Pot Mag. Side
Completed: X7.7(WPMS.M) –SL32 Waiting Pot Mag. Side
★ AL 2291 "Waiting Pot Spd/Mag. Side Alarm" occurs
Check: X7.6(WPSS.M) –SL36 Waiting Pot Spindle Side
No
X7.7(WPMS.M) –SL32 Waiting Pot Mag. Side
Output: Y12.2(SCS1.R) –YV33 Sub Changer Pos. 1
Y12.3(SCS2.R) –YV34 Sub Changer Pos. 2
Y12.4(SCS3.R) –YV35 Sub Changer Pos. 3
Y12.5(SCS4.R) –YV36 Sub Changer Pos. 4
Completed: X10.5(SCWP.M) –SX35
Pos.
★ AL 2272 "ATC Sub Changer Pos. Check Alarm" occurs
Check: X10.3(SCHP.M) –SX33 Sub Chan. Home Pos.
No
X10.4(SCPP.M) –SX34 Sub Chan. Pot Pos.
X10.5(SCWP.M) –SX35 Sub Chan. Wait. Pos.
Output: Y12.1(SCAT.R) –YV32 Sub Changer Arm Out
Completed: X10.2(SCAO.M) –SL32 Sub Changer Arm
Out
★ AL 2273 "ATC Sub Tool In/Out Alarm" occurs
No
Check: X10.2(SCAO.M) –SL32 Sub Changer Arm Out
X10.1(SCAO.M) –SL31 Sub Changer Arm In
Output: Y12.2(SCS1.R) –YV33 Sub Changer Pos. 1
Y12.3(SCS2.R) –YV34 Sub Changer Pos. 2
Y12.4(SCS3.R) –YV35 Sub Changer Pos. 3
Y12.5(SCS4.R) –YV36 Sub Changer Pos. 4
Completed: X10.4(SCPP.M) –SX34 Sub Chan. Mag. Pos.
★ AL 2272 "ATC Sub Changer Pos. Check Alarm" occurs
Check: X10.3(SCHP.M) –SX33 Sub Chan. Home Pos.
No
X10.4(SCPP.M) –SX34 Sub Chan. Pot Pos.
X10.5(SCWP.M) –SX35 Sub Chan. Wait. Pos.
HM4digitATCE26
On
On
Off
On
On
Off
On
Off
Sub Chan. Wait.
On
Off
Off
On
On
On
On
Off
Off
On
On
Off
On
Off
On
Off