Astria ValiantOD42P3 설치 및 작동 지침 매뉴얼 - 페이지 3
{카테고리_이름} Astria ValiantOD42P3에 대한 설치 및 작동 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Astria ValiantOD42P3 20 페이지. Outdoor vent-free firebox
1. Do not use this firebox as a wood-burning fireplace. Use only
decorative unvented room heaters (log sets).
2. Do not add extra logs or ornaments such as pine cones, vermiculite
or rock wool. Using these added items can cause sooting.
3. Use only provided hood or appropriate hood accessory. See Ac-
cessories on page 13.
4. Vent-free gas log heaters installed in these fireboxes require
fresh air ventilation to run properly. See Air for Combustion and
Ventilation, page 6.
5. Do not run heater in firebox
• where flammable liquids or vapors are used or stored
• under dusty conditions
6. Do not use heater in this firebox to cook food or burn paper or
other objects.
7. Turn installed heater off and let cool before servicing firebox. Only
a qualified service person should service and repair firebox.
8. Do not use the firebox if it has been under water due to the shock
hazard that could result with the blower accessary (if installed) in
place.
LOCAL CODES
Install and use with care. Follow all local codes. In the absence of
local codes, use the latest edition of The National Fuel Gas Code, ANSI
Z223.1/NFPA 54*. Firebox must be electrically grounded in accor-
dance with the National Electrical Code, ANSI/NFPA70 (latest edition).
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
PRODUCT FEATURES
PRODUCT FEATURES
OPERATION
This firebox has been tested and approved under ANSI Z21.91 for use
with any gas log approved to ANSI Z21.11.2 for indoor applications
and ANSI Z21.97 for outdoor applications. (Physical size limitations
apply. Refer to minimum firebox requirements supplied with log
heater.) It requires no outside venting or chimney making installation
easy and inexpensive. When used without blower, heater installed in
firebox requires no electricity making it ideal for emergency backup
heat.
REFRACTORY BRICK LINER
Your firebox may feature a concrete refractory brick liner. As with all
concrete liners, this liner may develop slight cracks when exposed
to heat. These cracks will not affect performance of fireplace or
vent-free gas logs.
OUTSIDE AIR KIT ACCESSORY
An optional AK4 air kit provides additional outdoor air to improve burner
efficiency and reduce build-up of condensation in the living space. Follow
instructions included with air kit.
126773-01B
SAFETY Continued
State of Massachusetts: The installation must be made by a
licensed plumber or gas fitter in the Commonwealth of Mas-
sachusetts.
Sellers of unvented propane or natural gas-fired supplemental
room heaters shall provide to each purchaser a copy of 527 CMR
30 upon sale of the unit.
Vent-free gas products are prohibited for bedroom and bathroom
installation in the Commonwealth of Massachusetts.
COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS
These appliances are approved for installation in the US state of
Massachusetts if the following additional requirements are met:
•
Un-vented Room Heaters shall be installed in accordance with
527 CMR 30.
•
Installation and repair must be done by a plumber or gas fitter
licensed in the Commonwealth of Massachusetts.
•
The flexible gas line connector used shall not exceed 36 inches
(92 centimeters) in length.
•
The individual manual shut-off must be a T-handle type valve.
•
Unvented appliances may NOT be installed in bedrooms or
bathrooms.
•
A working smoke detector must be installed in the area where
vent-free appliances are installed.
Seller of unvented propane or natural gas-fired supplemental room
heaters shall provide to each purchaser a copy of 527 CMR 30 upon
sale of the unit.
PLANNING
Plan where you will install the firebox. This will save time and money
later when you install the firebox. Before installation, consider the
following:
1. Where firebox will be located: Allow for wall and ceiling clearances
(see Installation Clearances, page 8).
2. Everything needed to complete fireplace installation.
3. These models CANNOT be installed in a bedroom unless maximum
Btu rating of installed vent-free log set is less than 10,000 Btu/hr.
4. Proper air for combustion and ventilation (page 6).
Astria.US.com
LOCATING FIREBOX
3