Flying Industry Development S1F2-DC06 빠른 매뉴얼 - 페이지 2
{카테고리_이름} Flying Industry Development S1F2-DC06에 대한 빠른 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Flying Industry Development S1F2-DC06 2 페이지. Rf wireless remote control dc motor controller / transmitter & receiver
Flying Industry Development S1F2-DC06에 대해서도 마찬가지입니다: 빠른 매뉴얼 (2 페이지)
motor will work in reversal direction; when the restrictive switch "X1" is disconnected,
"X2" is connected, the motor will
When you don't want to use the restrictive switches, you need to connect the terminals "X1" and "X2"by two wires.
Learning the button of transmitter:
1) Press and hold "K3" button of receiver 1; when signal LED on the receiver 1 is on, release "K3" button. Press the left ▲ button of transmitter
within 5 seconds, if the signal LED off, that means learning is successful.
2) Press and hold "K1" button of receiver 1; when signal LED on the receiver 1 is on, release "K1" button. Press the left ▼ button of transmitter
within 5 seconds, if the signal LED off, that means learning is successful.
3) Press and hold "K2" button of receiver 1; when signal LED on the receiver 1 is on, release "K2" button. Press the left
within 5 seconds, if the signal LED off, that means learning is successful.
4) Press and hold "K3" button of receiver 2; when signal LED on the receiver 2 is on, release "K3" button. Press the right ▲ button of transmitter
within 5 seconds, if the signal LED off, that means learning is successful.
5) Press and hold "K1" button of receiver 2; when signal LED on the receiver 2 is on, release "K1" button. Press the right ▼ button of transmitter
within 5 seconds, if the signal LED off, that means learning is successful.
6) Press and hold "K2" button of receiver 2; when signal LED on the receiver 2 is on, release "K2" button. Press the right
within 5 seconds, if the signal LED off, that means learning is successful.
Delete the button of transmitter:
We have learned transmitter to the receiver. If you don't want the receiver to work with transmitter, you can delete all codes of transmitter which
are stored in the receiver. You can operate as following:
Press and hold "K3" button of receiver more 3 seconds; when signal LED on the receiver begin to flicker, then off, that means deleting is
successful.
Press and hold "K1" button of receiver more 3 seconds; when signal LED on the receiver begin to flicker, then off, that means deleting is
successful.
Press and hold "K2" button of receiver more 3 seconds; when signal LED on the receiver begin to flicker, then off, that means deleting is
successful.
Note: Before you change from motor rotates in positive direction to reversal direction or from motor rotates in reversal direction to positive
direction, you should stop rotating of motor firstly, then remote control motor.
Application Circuit
RF module
Antenna
IC
Signal LED
Relay
OUTPUT
Restrictive switches
M
DC Motor
X1
When you use the restrictive switches
work in positive direction; when the restrictive switch "X2" is disconnected, motor will stop automatically.
Jumper S1
Jumper S2
K1
K2 K3
Relay
Power LED
INPUT
_
+
X2
Power supply
SHENZHEN GUIYUAN INDUSTRY DEVELOPMENT CO.,LTD
Http://www.carymart.com
motor will stop automatically. When the restrictive switch
Application Circuit
RF module
Antenna
IC
Signal LED
Relay
OUTPUT
Restrictive switches
M
DC Motor
X1
When you don't use the restrictive switches
E-Mail: [email protected]
button of transmitter
button of transmitter
Jumper S1
Jumper S2
K1
K2 K3
Power LED
Relay
INPUT
_
+
X2
Power supply