Coiltek CS-5000 V2 운영 매뉴얼 - 페이지 14
{카테고리_이름} Coiltek CS-5000 V2에 대한 운영 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Coiltek CS-5000 V2 20 페이지.
Presets
The graphic below shows the binary address scheme for programming and retrieving programmed
presets manually. The switch setting in place at the time of set-up dictates where that particular set-up
is stored. Removal of the jumper from W1, as with any of the set-up parameters, makes the preset(s)
programmed non-volatile.
If you frequently switch between several presets, you may want to consider integrating a 3CPO
accessory into your unit. This 3- position selector switch allows for immediate, remote access to
presets. Please also see the section on programming your presets with our CSWin software.
Diagnostics
The operation of the ranging card with the main processor card is as follows. The main board emits a
START pulse. The range card replies with two consecutive pulses: the first is a START acknowledge
pulse, the second is the ECHO return pulse. The time between these two pulses is used by the main
board to calculate the distance measurement. Normally, the LEDs D2 and D3 on the main board, as
well as the LED on the end of the sensor arm, indicate the position of the target as follows:
• Above the control range, RED or, after 11-2018, blinking red
• In the control range, GREEN
• Below the control range, RED
If the main board receives no second or ECHO return signal, the position indicator LEDs both turn on.
If no START ACKNOWLEDGE pulse returns, these LEDs blink back and forth periodically. This
would also happen should the range card become disconnected.
12