Usage:
The receiver can be used to control both DC 0~28V and AC 110~240V equipments.
Notice: The receiver is relay output, not DC/AC power output. Initial state of relay output terminals: Terminals B and C are Normally Open; Terminals
A and B are Normally Closed.
Wiring:
If you want to control a DC 12V lamp, do as following:
1) Connect the positive pole of DC power supply to terminal "+" of INPUT, and connect the negative pole of DC power supply to terminal "-" of INPUT.
2) Connect terminal C to the positive pole of DC power supply, connect terminal B to the positive pole of DC lamp, and connect the negative pole of
DC lamp to the negative pole of DC power supply.
If you want to control an AC 220V lamp, do as following:
1) Connect the positive pole of DC power supply to terminal "+" of INPUT, and connect the negative pole of DC power supply to terminal "-" of INPUT.
2) Connect terminal C to the live wire of AC power supply, connect terminal B to one side of AC lamp, and connect another side of AC lamp to the
neutral wire of AC power supply.
Setting different control modes:
Setting different control modes (We have set the receiver as Toggle mode before delivery. If you want to use other modes, do as following):
Setting control mode Toggle: Only connect Jumper-2.
Control mode Toggle (with the transmitter CV-12): Press -> On; Press again -> Off.
Press button 1: Turn on relay 1 of Receiver 1 (connect B and C, disconnect A and B), the lamp 1 is on.
Press button 1 again: Turn off relay 1 of Receiver 1 (disconnect B and C, connect A and B), the lamp 1 is off.
Press button 2: Turn on relay 2 of Receiver 1 (connect B and C, disconnect A and B), the lamp 2 is on.
Press button 2 again: Turn off relay 2 of Receiver 1 (disconnect B and C, connect A and B), the lamp 2 is off.
...
Press button 11: Turn on relay 1 of Receiver 6 (connect B and C, disconnect A and B), the lamp 11 is on.
Press button 11 again: Turn off relay 1 of Receiver 6 (disconnect B and C, connect A and B), the lamp 11 is off.
Press button 12: Turn on relay 2 of Receiver 6 (connect B and C, disconnect A and B), the lamp 12 is on.
Press button 12 again: Turn off relay 2 of Receiver 6 (disconnect B and C, connect A and B), the lamp 12 is off.
Setting control mode Momentary: Only connect Jumper-1.
Control mode Momentary (with the transmitter CV-12): Press and hold -> On; Release -> Off.
Press and hold button 1: Turn on relay 1 of Receiver 1 (connect B and C, disconnect A and B), the lamp 1 is on.
Release button 1: Turn off relay 1 of Receiver 1 (disconnect B and C, connect A and B), the lamp 1 is off.
Press and hold button 2: Turn on relay 2 of Receiver 1 (connect B and C, disconnect A and B), the lamp 2 is on.
Release button 2: Turn off relay 2 of Receiver 1 (disconnect B and C, connect A and B), the lamp 2 is off.
...
Press and hold button 11: Turn on relay 1 of Receiver 6 (connect B and C, disconnect A and B), the lamp 11 is on.
Release button 11: Turn off relay 1 of Receiver 6 (disconnect B and C, connect A and B), the lamp 11 is off.
Press and hold button 12: Turn on relay 2 of Receiver 6 (connect B and C, disconnect A and B), the lamp 12 is on.
Release button 12: Turn off relay 2 of Receiver 6 (disconnect B and C, connect A and B), the lamp 12 is off.
Setting control mode Latched (with the transmitter CV-12): Disconnect Jumper-1 and Jumper-2.
Control mode Latched: Press -> On, another relay Off; Press another button -> Off.
Press button 1: Turn on relay 1 of Receiver 1 (connect B and C, disconnect A and B), the lamp 1 is on.
Turn off relay 2 of Receiver 1 (disconnect B and C, connect A and B), the lamp 2 is off.
Press button 2: Turn on relay 2 of Receiver 1 (connect B and C, disconnect A and B), the lamp 2 is on.
Turn off relay 1 of Receiver 1 (disconnect B and C, connect A and B) the lamp 1 is off.
...
Press button 11: Turn on relay 1 of Receiver 6 (connect B and C, disconnect A and B), the lamp 11 is on.
Turn off relay 2 of Receiver 6 (disconnect B and C, connect A and B), the lamp 12 is off.
Press button 12: Turn on relay 2 of Receiver 6 (connect B and C, disconnect A and B), the lamp 12 is on.
Turn off relay 1 of Receiver 6 (disconnect B and C, connect A and B), the lamp 11 is off.
Setting control mode Momentary + Toggle (with the transmitter CV-12): Connect Jumper-1 and Jumper-2.
1) Control mode Momentary (Channel 1 of Receiver 1, 2, 3, 4, 5, 6): Press -> On; Press again -> Off.
Press and hold button 1: Turn on relay 1 of Receiver 1 (connect B and C, disconnect A and B), the lamp 1 is on.
Release button 1: Turn off relay 1 of Receiver 1 (disconnect B and C, connect A and B), the lamp 1 is off.
...
Press and hold button 11: Turn on relay 1 of Receiver 6 (connect B and C, disconnect A and B), the lamp 11 is on.
Release button 11: Turn off relay 1 of Receiver 6 (disconnect B and C, connect A and B) the lamp 11 is off.
2) Control mode Toggle (Channel 2 of Receiver 1, 2, 3, 4, 5, 6): Press and hold -> On; Release -> Off.
Press button 2: Turn on relay 2 of Receiver 1 (connect B and C, disconnect A and B), the lamp 2 is on.
Press button 2 again: Turn off relay 2 of Receiver 1 (disconnect B and C, connect A and B), the lamp 2 is off.
...
Press button 12: Turn on relay 2 of Receiver 6 (connect B and C, disconnect A and B), the lamp 12 is on.
Press button 12 again: Turn off relay 2 of Receiver 6 (disconnect B and C, connect A and B), the lamp 12 is off.