1)
Mix the san~tlzer (2 ounces of Steera Sheen green label or
4)
Turn the selector swltch to the "OFF" pos~t~on.
equ~valent) Into a clean pall c o n t a ~ n ~ n g two gallons of warm
water. T h ~ s solut~on will make a 200 P.P.M (parts per rnllllon)
ENERGYCONS
concentration of chlorlne sanitmng solut~on Pour the ~ o l u t l 0 n
into t h e mlx tanks.
IMPORTANT: Do not exceed the formula recommended b y the
sanitizer manufacturer as i t will not add to its effectiveness.
5) Using a sanitized soft bristle brush, brush the sides of the
mix tank, and all other product contact areas. Allow the
sanitizing solution to remain in contact with all product
contact areas for three to five minutes.
2) Pull the gravity feed tubes out of the mix tank holes and lay
them down in the tank. This will allow the cylinders to
c o m ~ l e t e l y fill with the sanitizing solution.
6) Place the clean, sanitized pail under the dispensing head
and open the handles by pulling them in a downward direction.
3) Turn the selector switch to the "BEATER" position for 30
seconds.