Dorex DX2 FW 설치 지침 매뉴얼 - 페이지 4
{카테고리_이름} Dorex DX2 FW에 대한 설치 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Dorex DX2 FW 16 페이지.
DOOR PREPARATION CHART
Fire Exit Hardware
is to be installed on
Fire Doors bearing
the marking "Fire
Door to be equipped
with Fire Exit
Hardware" Any
retrofit or other field
modification to a Fire
Rated opening can
potentially impact the
Fire Rating of the
opening.
RHR
Level
END CAP BRACKET 2-HOLES
SURFACE MOUNT
METAL
#25 DRILL
#10-24 TAP
WOOD
¹/8 " DRILL
PILOT 1" DEEP
PREPARE HOLES FOR THE END CAP BRACKET
MONTING HOLES AFTER THE EXIT DEVICE CENTER
CASE INSTALLATION AND AFTER LEVELING THE
EXIT DEVICE.
LATCHES
METAL
5/16" DRILL
ON DEVICE SIDE
13/32" DRILL
ON TRIM SIDE
WOOD
13/32" DRILL
THRU
ROD GUIDES
METAL
#25 DRILL
#10-24 TAP
WOOD
1/8" DRILL
PILOT HOLE 1" DEEP
OUTSIDE
LHR
INSIDE
RHR shown(LHR opposite)
C L
SEX BOLTS
METAL
1/4" DRILL
(DEVICE SIDE)
DRILL
¹³/32"
(TRIM SIDE)
WOOD
¹³/32"
DRILL THRU
USE APPROPRIATE
TEMPLATE FOR THE
SUPPLIED STRIKE
TOP STRIKE
METAL
#25 DRILL
#10-24 TAP
1/8" DRILL
PILOT HOLE , 1" DEEP
IMPORTANT:
• Use supplied templates for field installations.
• Use door preparation documents for door/frame manufacturing.
• Door must be properly reinforced where the exit device chassis and latches
are mounted. The surface must be flush and flat within 1/16" (1.5 mm).
• Prepare the interior of the door using the exit device template or door
preparation and instructions.
• Prepare the exterior of door using the trim template or door preparation and
installation instructions.
• All threaded holes require a minimum material thickness of 0.125" (3 mm).
• We recommend samples be used to verify preparation before mass door or
frame manufacturing.
• NOT RESPONSIBLE for any physical or property damage due to incorrect /
improper preparation or installation.
CENTER CASE 2-HOLES
SURFACE
MOUNT
METAL
#7 DRILL
#1/4"-20 TAP
X
N/A
C L
CENTER CASE 2-HOLES
X
DEVICE SIDE ONLY ⁵/8" DEEP FOR
SEE TRIM INSTALLATION INSTRUCTIONS, TEMPLATES, OR
DOOR PREPARATION DOCUMENTS FOR DETAILS.
BOTTOM STRIKE
USE SUPPLIED MOUNTING
HARDWARE OR APPROPRIATE
FLOOR ANCHORS FOR THE
APPROPRIATE BOTTOM STRIKE
4 / 16
FOR DOOR PREPARATION
REFERENCE ONLY.
Verify that this is the latest version of
WOOD
this document. We recommend
samples be used to verify preparation
before door / frame manufacturing.
FOR THRU BOLTS
OR TRIM
METAL
5/16" DRILL ON DEVICE SIDE
13/32" DRILL ON EXTERIOR SIDE
(FOR THRU BOLTS)
1/2" DRILL THRU HOLE
(FOR TRIM POSTS)
WOOD
13/32" DRILL THRU
(FOR THRU BOLTS)
1/2" DRILL THRU HOLE
(FOR TRIM POSTS)
SURFACE MOUNT
METAL
#25 DRILL
#10-24 TAP
WOOD
1/8" DRILL
PILOT HOLE 1" DEEP
DOOR CUT-OUTS
CUT-OUT
WOOD DOOR
¹/4 " Radi us