Addressable Curtain PIR Motion Detector
GENERAL
S2000-IK Revision 04 Addressable Curtain Passive Infrared (PIR) Motion Detector (hereinafter referred to as the
detector) is designed to be used indoors. It detects intrusion into protected areas and sends an alarm message to the
connected S2000-KDL controller via the two-wire multiplex addressable polling loop.
The S2000-IK rev.04 has a two-dimensional coverage pattern ("vertical curtain").
The detector provides increased immunity against lighting and radio frequency interference.
KEY FEATURES
Dual-element pyro-electric infrared sensor
High-density coverage offering high probability of detecting an intruder
Protected against insects entering to the pyro-electric infrared sensors
Arranging sabotage-resistant zones just beneath the detector prevents unauthorized access to the detector.
Digital signal processing
Powered via the multiplex addressable polling loop of the S2000-KDL
Supports DPLS_v2.xx protocol
SPECIFICATIONS
Detection Range
Coverage Pattern
Input Voltage (from a S2000-KDL)
Current Consumption (via the loop of the S2000-KDL)
Horizontal Angle of Sight
Operating Temperatures
Humidity
Overall Dimensions (H x W x D)
Weight
Mounting Height
MOUNTING LOCATION CONSIDERATIONS
The detector is intended to be used indoors. Considering a
location to mount the detector, please take into account that
the detection zone must not be obscured by any non-
transparent objects such as curtains, houseplants, cabinets,
room dividers, etc. as well as by glass or mesh partitions.
Do not locate the detector where it can be exposed to false
alarm sources such as windows, air conditioners, heaters,
radiators, etc.
Wires of the multiplex addressable polling loop should be
located away from high-voltage electric cables.
The detector allows wall or corner mounting at a height of
2.3 m above the floor. This provides the detection range at
least 10 meters. The detection pattern is shown in Figure 1.
INSTRUCTION MANUAL
10 m
Curtain (two-dimensional)
8 ÷ 10 VDC
0.5 mA max when indication is off
6°
−30 to +50° C
95% at 25° C, non-condensing
105 mm × 75 mm × 56 mm max
0.1 kg max
2.3 meters
Figure 1: S2000-IK Rev.04 Detection Pattern