This status maintains until next operation is done. When Power On is executed, the
information of temperature anomaly is canceled and normal operation is executed.
"24" [CR]
Status: Processing Power Save / Cooling Down
Power management function in Setting menu works and the status goes to Power Save
/ Cooling Down.
During this time, Functional Execution Commands are invalid (not executed).
This status moves to Power Save at set hours after the operation of Cooling Down.
Status
No signal
Response
"00"
5 minutes with no signal
"04" [CR]
Status: Power Save
This shows that it moves to Power Save status by Power management function in
Setting menu.
"21" [CR]
Status: Cooling Down in process after turned off due to lamp failure
When a projector is turned off because of lamp failure, it automatically starts Cooling
Down operation, in which the projector returns "21" [CR].
"81" CR
Status: Standby after Cooling Down due to lamp failure
This value is returned when Cooling Down operation due to lamp failure has been
completed and the status has been moved to Standby. The status is kept until the next
operation starts.
Power Save / Cooling Down
"24"
-21-
Basic Serial Command Specifications
Power Save
"04"
After about 90 sec.