FRAME PREPARATION (RHRB SHOWN)
Drawing shows only one method of installation. Method
of installation may vary per door manufacture.
BACK BOX PROVIDED BY HOLLOW METAL MANUFACTURER
TO KEEP DUST AND DIRT OUT OF STRIKE POCKET.
CONSTRUCT BOX IN A MANNER THAT IT WILL HOLD ITS SHAPE.
(16 GAUGE MIN.)
(51)
1-5/16
.875 DIA CONDUIT
KNOCKOUTS PUNCHED
AS REQ'D
REINFORCE JAMB
FOR TAPPED HOLES
(10 GAUGE MIN)
2 PLACES
2
MIN
MIN
(33)
5-1/2
MIN
(140)
5/8
(16)
5-1/2
MIN
(140)
STRIKE PREP LOCATION
Measure distance from the mounting surface to tip of bolt.
This is DIM X.
DIM Y = DIM X + 3/32" (2mm).
DIM Y is from edge of stop to centerline of prep.
Calculation assumes 3/32" (2mm) thick silencer bumper.
VERTICAL CENTER LINE
#8 DRILL (.199)
OF ELECTRIC STRIKE & LATCH BOLT
TAP 1/4-20 UNC
OF LOCK MUST ALIGN.
THRU 2 PLACES
3-3/32
(79)
8-1/4
(210)
1-11/16
(43)
7-7/8
(200)
DIM Y
21/32
08101631
INS NO.
DIM X
DORMA 9300 DEVICE
WITH DEADLATCH
C
L
(17)
1-5/16
(33)
6 of 7
PAGE
05/09