{카테고리_이름} Cansec MAP2에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Cansec MAP2 16 페이지. Elevator control
Elevator MAP2 Panel must be provisioned by Cansec each time an additional add-on H1000 is added
64 FLOOR ELEVATOR SYSTEM
This configuration is used when connecting to an elevator of up to 64 floors. This consists of one
MAP1 elevator control panel and three H1000 panels.
MAP2 Elevator Panel
H1000 Panel 2: Controls floors 33- 48
Controls floors 1 to 16
H1000 Panel 3: Controls floors 49- 64
H1000 Panel 1: Controls floors 17- 32
RS485 communication wires
MAP2 Elevator Control
Page 10 of 16
Installation Guide
April 2020 • Rev. 1.0