Dormakaba 8900 T 설치 지침 매뉴얼 - 페이지 3

{카테고리_이름} Dormakaba 8900 T에 대한 설치 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Dormakaba 8900 T 8 페이지. Emf surface applied closer (no detector)
Dormakaba 8900 T에 대해서도 마찬가지입니다: 설치 지침 매뉴얼 (10 페이지)

Dormakaba 8900 T 설치 지침 매뉴얼
dormakaba 8900 T/TH Installation Instructions
1  Technical specifications
1.1

Overview

Caution: sex nuts are required for attachment
of components to unreinforced doors and to
wood or plastic faced composite type fire doors,
unless an alternative method is identified in the
individual door manufacturer's listings.
Maximum door opening degree is 180°.
Arrow on backplate points downward.
Hold open range is from 80° to 160° with
optional hold open kit.
1.2

Tools recommended

Table 1
Drill bits:
Metal: 7/32" drill bit; 1/4-20
tap
Wood: 3/8" and 5/32" bit
1/2" box wrench

1.3 Handing the door

Fig.1
Left hand door (LH)
Hinge
8900 Surface Applied Closers
#3 Phillips screwdriver
3/16" flat head screwdriver
5mm hex key
Interior side of door
08280121
Know the swing of the door which is being
installed prior to installation.
Verify closer spring size prior to installation.
Make sure door efficiently operates prior to
installing closer.
Right hand door (RH)

Technical specifications

Hinge
09-2019
3