dormakaba 8900 EMF Installation Instructions
3.3 Adjust hold open
Fig.9
Hold open position is preset at approximately 90°. Loosen set screws using 3/32" hex wrench. Slide hold open
device to desired position. Retighten set screws securely.
Greater Hold Open Angle
Hold open force adjustment - 5/32 hex.
Clockwise = stronger
3.4 Auxiliary stops
Fig.10
An auxiliary door stop (by others) must be installed to limit the maximum degree
of door swing. Failure to do so may result in damage to the unit.
4
Bypass switch (optional)
4.1 Secure bypass switch
Fig.11
4.1.1 Slide wiring connection cover to allow access.
8900 EMF
8
Hold open device
Hold open set screws -
3/32" hex
Wire connection
cover
08281000
4.1.2 Attach bracket and assembly bypass switch.
Adjustments: hold open
Auxiliary stop
Bypass switch
Less Hold Open Angle
NOTE: Power must be
supplied to reset position.