Care and Maintenance Instructions Model : Z2108
MAINTENANCE FOR THREE HOLE/TWO LEVER TAPWARE
INSTRUCTIONS FOR REPLACEMENT OF THE HOT OR COLD CARTRIDGE
Do not replace the cartridge if there is low flow or no flow. Low flow or no flow is caused by obstruction or
kinking of supply hoses.
❶
If the hand spray is leaking, do not replace the diverter. Service or replace the hand
Turn off the hot and cold supply lines to the tap set.
(Not shown).
spray if there is a continous leak.
Remove the handle and retaining flange. Refer to
"Removing and replacing a handle" section,
page10.
❸
Install new cartridge.
Secure the cartridge with a smooth jawed shifter.
Note: Do not over tighten as this could damage the ceramic
cartridge!
Further information Phone (03) 9761 4603
11
❷
Remove the cartridge with a smooth jawed 17mm
shifter.
❹
Install lever and retaining flange. DO NOT USE A
SHIFTER TIGHTEN BY HAND ONLY!
Turn on supply line and test for leaks. (Not shown).
Continue.......