Care and Maintenance Instructions Model : Z2225
MAINTENANCE FOR WALL MOUNTED TWO LEVER TAP WARE
INSTRUCTIONS FOR REPLACEMENT OF THE HOT OR COLD CARTRIDGE
Do not replace the cartridge if there is low flow or no flow. Low flow or no flow is caused by obstruction or
kinking of supply hoses.
Turn off the hot and cold supply lines to the
❶
If the hand spray is leaking, do not replace the diverter. Service or replace the hand
tap. (Not shown).
Remove the handle and retaining flange.
spray if there is a continous leak.
Install new cartridge.
❸
Secure the cartridge with a 17mm spanner or
smooth jawed shifter.
Note: Do not over tighten as this could damage the ceramic cartridge!
Further information Phone (03) 9761 4603
6
❷
Remove the cartridge with a 17mm spanner or
smooth jawed shifter.
Install the handle and retaining flange, and hand
❹
tighten only. DO NOT USE A SHIFTER TIGHTEN BY
HAND ONLY!
Turn on supply line and test for leaks. (Not
shown).