Advance Appliances EG 12 설치 및 사용자 설명서 - 페이지 9
{카테고리_이름} Advance Appliances EG 12에 대한 설치 및 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Advance Appliances EG 12 12 페이지. Electric boiler 6, 9 & 12kw
EGLOW PROBLEM SOLVING
Note: Main fault modes LED7 Red Cont – Flow Switch
Red Flashing – overheat Green – All ok
Check voltage input at the terminal is between 207v-
245v. Note voltage during commissioning should be
checked when the pods are ac ve to ensure the voltage
does not go below the minimum level.
Yes
Check voltage input R/H
contactor
Yes
Check ZERO voltage demand and
switch on. Contactor should
switch on
Yes
LED 6 lit on PCB
Yes
Check for 12v D.C as below
Yes
No
No
No
No
No
Replace board
Go back to source and
check wiring
Faulty wires from block to
contactor
Check the wires from the
demand terminal to the board. If
ok replace contactor
Check fuse 3.15A fast
ac ng 20 mm
9