DAF LF55 Series 유지 관리 일정 - 페이지 9
{카테고리_이름} DAF LF55 Series에 대한 유지 관리 일정을 온라인으로 검색하거나 PDF를 다운로드하세요. DAF LF55 Series 12 페이지.
EXPLANATORY NOTES ON THE MAINTENANCE ACTIVITIES
ΛΦ45/55 series
6. CLEANING
6.1 CLEANING THE BATTERY TERMINALS
}
Avoid sparks and open flames in the
vicinity of batteries. Battery acid is
an aggressive fluid.
In the event of contact with the skin:
rinse the skin with plenty of water for
a sustained period. If redness or
pain persists, consult a doctor.
Remove any clothing affected and
rinse with water.
In the event of contact with the eyes:
rinse with plenty of water for at least
15 minutes and consult a doctor.
If swallowed: do NOT induce
vomiting. Rinse the mouth, drink two
glasses of water and consult a
doctor.
In the event of inhalation: get fresh
air, rest and consult a doctor.
1.
Disconnect the earth lead from the battery
terminal.
2.
Disconnect the positive lead from the battery
terminal.
3.
Clean the battery terminals, battery cables
and the top of the battery (oxide and dirt
discharge the battery).
4.
If the top of the battery has acid on it, it
should be rinsed with water.
5.
Check the fastening of the earth cable
connection to the chassis. Grease the
connection with petroleum jelly.
6.
Check the connection between the cable and
the fuse holder located behind the batteries;
see the arrow in the illustration. Clean the
connection and grease it with petroleum jelly.
7.
Fit the positive lead to the battery terminal.
8.
Fit the earth lead to the battery terminal.
9.
Grease the battery terminals with petroleum
jelly.
10. Check the routing and attachment of the
battery cables.
©
200515
Cleaning
5
G0 00 227