Dot-x DNR V SERIES 사용자 설명서 - 페이지 4

{카테고리_이름} Dot-x DNR V SERIES에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Dot-x DNR V SERIES 10 페이지. 25 inch display
Dot-x DNR V SERIES에 대해서도 마찬가지입니다: 사용자 설명서 (12 페이지)

TO ACTIVATE MENUS AND CONTROLS
Stand in front of the unit (monitor) and aim the remote at the InfraRed (IR)
receiver located on the lower right corner of the unit. Press and hold the ENTER
key on the remote for several seconds (typically 6 to 8 seconds).
The following on screen display (OSD) will appear.
MODEL DNR 5 by DOTRONIX
TO ACTIVATE MENUS AND CONTROLS
KEY IN SECURITY CODE:
THEN PRESS ENTER KEY
The factory set security code is 5432. You can change this code at any time.
Refer to a later section of this manual titled CHANGING SECURITY CODE
AND UNIT NUMBER. At this point key in the security code 5432. As each
number is pressed, an x will appear after the KEY IN SECURITY CODE: line.
If you miss-key a number the x's will disappear allowing you another chance
to enter the code. When the correct code is entered, press the ENTER key.
The following on screen display (OSD) will appear.
TO ACTIVATE THIS SET KEY IN 01
KEY IN SET #:
All units are shipped from the factory programmed as unit # 01. For multiple
unit installations, you will want to change the unit number of all but one unit
to other numbers. Typically the units are numbered in sequence from 01
upward. The DNR 5 HARC will accept unit numbers up to 99. (If you need more
than 99, consult the factory for a special program.) At this point, key in 01,
the numbers will appear after the colon. If you miss-key the number, simply
key in the desired number, the new number will replace the miss-keyed
number. When you are satisfied with the number, press the ENTER key.
4

CUSTOM OPTIONS

LOST OR FORGOTTEN SECURITY CODE
A lost or forgotten security code can be handled by temporarily installing the
jumper which opens the new security code screen. After installing the jumper
use the remote control to change the security code as described in the
CHANGING SECURITY CODE AND UNIT NUMBER. When the new code is
saved, remove the temporary jumper and security will be re-activated with the
new code.
If the new security code screen does not appear after installing the jumper,
remove and restore power to the unit with the jumper in place.
Remove this to
access board.
Rear of Cabinet
Position the jumper
as shown to reset
security code.
Top View of Addressable Board
14
16
13 15
Position the jumper
as shown above
when not in use.
17