EDITING SHOW PARAMETERS
Software record lockout
The Rerun Rackmount has a software record lockout feature. When the software record lockout is
enabled, no shows can be recorded and no parameter data can be modified.
To alter the software record lockout status, do the following:
1.
Start playing any show.
2.
Pause the show at any point.
3.
Press and hold the number 10 [SHOW] button. Hold the number 10 [SHOW] button for about five
seconds. While held, the remaining [SHOW LEDS] will indicate the status of other show and
system parameters. The number 1 [SHOW LED] indicates the status of the software record lockout
output option. While continuing to hold the number 10 [SHOW] button, press the number 1 [SHOW]
button to toggle the state of the option. When the number 1 [SHOW LED] is lit, the Rerun
Rackmount will not allow any show or parameter data to be changed. When the number 1 [SHOW
LED] is off, the Rerun Rackmount will allow changes to be made. Set the software record lockout
option as desired.
4.
Release the number 10 [SHOW] button.
5.
Press the [PAUSE] button to save the new settings and to resume the show.
Note:
!
The software record lockout feature is a global system parameter. Although it can be accessed from any show,
there is only one record lockout state.
!
By default, the software record lockout feature is disabled (recording enabled).
Front panel lockout
The front panel buttons on the Rerun Rackmount can be locked to prevent tampering with a running show.
The ability to lock out the front panel is disabled by default.
To enable or disable the ability to lock the front panel, do the following:
1.
Start playing any show.
2.
Pause the show at any point.
3.
Press and hold the number 10 [SHOW] button. Hold the number 10 [SHOW] button for about five
seconds. While held, the remaining [SHOW LEDS] will indicate the status of other show and
system parameters. The number 4 [SHOW LED] indicates the status of the front panel lockout
output option. While continuing to hold the number 10 [SHOW] button, press the number 4 [SHOW]
button to toggle the state of the option. When the number 4 [SHOW LED] is lit, the Rerun
Rackmount will allow the front panel to be locked. When the number 4 [SHOW LED] is off, the
Rerun Rackmout will not allow the front panel to be locked. Set the front panel lockout enable
option as desired.
4.
Release the number 10 [SHOW] button.
5.
Press the [PAUSE] button to save the new settings and to resume the show.
Note:
!
The front panel lockout enable feature is a global system parameter. Although it can be accessed from any show, there
is only one front panel lockout enable state.
!
By default, the front panel cannot be locked.
!
See the Front panel lockout section in the LOCKING THE FRONT PANEL section for operational details.