TROUBLESHOOTING

PROBLEM
Air Scrubber does
not turn on
Air Scrubber starts
and then shuts off
Air Scrubber vibrates
Air Scrubber change light
illuminated
Motor makes noises, but
Air Scrubber won't turn on
Thank you for purchasing this product. Please read the instructions
carefully and follow all warnings. All products are manufactured to be
easy to use and provide years of worry free service when the
recommendations in this manual are followed. Please call at with any
questions or concerns.
POSSIBLE CAUSE/SOLUTION
• Switch not turned on – turn on
• Circuit breaker or GFCI has tripped - push reset button
• No power to scrubber – make sure unit is plugged in; check power supply
• Faulty switch - replace
• Obstructed inlet/outlet – remove obstruction
• Faulty motor - replace
• Motor shaft is bent – replace motor
• Fan blade is bent – replace
• Excessive dirt built up on fan blade – clean by wiping with a
slightly damp cloth.
• HEPA filter needs replacement - replace
• Air intake restricted – remove restriction or bends/kinks in ducting
• Damaged/faulty motor or motor shaft – replace
• Broken/loose wire to capacitor – tighten
• Damaged/faulty capacitor – replace
• Damaged housing/fan so fan will not spin – replace housing or fan wheel
• Motor shaft set screw holding fan wheel is loose - tighten