Doug Fleenor Design E8ANL-DIN 구성 매뉴얼 - 페이지 11
{카테고리_이름} Doug Fleenor Design E8ANL-DIN에 대한 구성 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Doug Fleenor Design E8ANL-DIN 12 페이지. 8 channel ethernet to analog interface
The Signal Loss page is used to configure the interface's behavior upon loss of signal.
You can configure the Signal Loss Mode to have all the outputs go to Zero or have all
the outputs go to Full. In addition, you can overwrite this configuration setting by
removing the 'Hold Last Look' Jumper (JP1).
Jumper Settings
The E8ANL-DIN has three jumpers, JP1 through JP3, which select different feature
options. The factory default is to have all jumpers installed.
JP1
With JP1 installed, the E8ANL-DIN uses the signal loss configuration to
determine its signal loss behavior. When removed, the 'Hold Last Look' function
is selected. This overrides the Signal Loss setup option.
JP2
With JP2 installed, the E8ANL-DIN operates normally. When removed, access to
the webserver is disabled and configuration changes are not possible. NODE
Discovery will still discover the E8ANL-DIN on the network, but the webserver
cannot be accessed.
JP3
With JP3 installed, the E8ANL-DIN operates normally. When removed at power
up, this jumper resets all default settings to the factory configuration values.
Caution: Removing this jumper will cause you to lose your settings and will reset the
E8ANL-DIN's IP Address to 10.10.10.10 and the Subnet Mask to 255.0.0.0.
Page 11 of 12