Baumer Clever Level LBFH 사용 설명서 - 페이지 11

{카테고리_이름} Baumer Clever Level LBFH에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Baumer Clever Level LBFH 34 페이지. Point level detection – hygienic/industrial

Baumer Clever Level LBFH 사용 설명서
Process conditions
Type
Process connection
LBFI
G 1/2 A ISO 228-1
LBFI
1/2-14 NPT
LBFH/I
G1/2 A hygienic
The temperature specifications apply to a maximum dip depth of the sensor tip into the process area of
20 mm.

14. Configuration overview

14.1 "Media separation" example of configuration
BU
14.2 "Excluding media adhesion" example of configuration
I
Signal (%)
1
2
3
0
20
50
1
Good conductive medium
2
Adhesion from good conductive adhesive
medium
3
Oily medium
4
Air
www.baumer.com
YE
GN
II
4
80
100
Sweep Range (%)
Operating Instructions
Level measurement
CleverLevel
Point level detection – hygienic/industrial
BCID
Process
temperature
continuous
[°C]
T
< 50 °C
amb
G07
-40 ... 115
N02
-40 ... 115
A03
-40 ... 115
BU = blue: SW1 active
„
„
YE = yellow: SW2 active
„
„
GN = green: Both switch outputs inactive.
„
„
Example of configuration for a vessel that can
be filled with either a good conductive adhesive
medium (e.g. fruit preparation) or with an oily
medium (e.g. chocolate mix).
Switch windows I and II are set so that for example
the fruit preparation (1) is detected, adhesion from
fruit preparation (2) is excluded and the chocolate
mixture (3) identified.
In the process, switch window I goes to SW1 and
switch window II to SW2.
®
LBFH/I
Process
Process
pressure
temperature
t < 1 h
[bar]
[°C]
T
< 50 °C
amb
-1 ... 100
135
-1 ... 100
135
-1 ... 10
135
Process
pressure
t < 1 h
[bar]
-1 ... 100
-1 ... 100
-1 ... 5
11 / 33