Baumer CleverLevel LBFS Series 사용 설명서 - 페이지 7
{카테고리_이름} Baumer CleverLevel LBFS Series에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Baumer CleverLevel LBFS Series 48 페이지. Level measurement, point level detection
5.2 Installation for hygiene applications
WARNING
Danger to health from contaminated medium
Only use weld-in sleeves or adapters from Baumer.
f
Do not seal process connections with Teflon tape (PTFE) or elastomer.
f
Welding work must only be carried out by welders trained in the area of hygiene.
f
1
2
www.baumer.com
Level measurement
CleverLevel
Point level detection
LBFS with the following process connections:
M18x1 ISO 965 (BCID M11)
9 Vessel and pipelines are free of media.
Screw in sensor.
f
Tighten the nuts on both sides.
f
Tightening torque: 15...20 Nm
LBFS with the following process connection:
G 1/2 A hygienic (BCID A03)
9 The weld-in sleeve or adapter must be
hygienically mounted and internally flush.
9 Weld seams are smoothed out to Ra < 0.8 µm.
9 Leakage hole points downwards.
Screw in sensor.
f
Tightening torque: 10...15 Nm
LBFS with the following process connection:
G 1/2 A hygienic with adjustable connection
(BCID A03)
9 The weld-in sleeve or adapter must be
hygienically mounted and internally flush.
9 Weld seams are smoothed out to Ra < 0.8 µm.
9 Leakage hole points downwards.
9 The clamping rings must be in faultless condition
(if they are deformed, replace both clamping
rings).
Push the wide clamping ring on to the guide
f
tube.
Push the narrow clamping ring on to the guide
f
tube.
Position the sensor.
f
Adjust the dip depth.
f
Projecting length: 15...228 mm
Tighten the screw-in pin.
f
Tightening torque: 10...15 Nm
Operating Instructions
®
LBFS
7 / 48