Example: Enable Tilt reverse
CAN-Identifier
18EFF753h
18EF53F7h
Example: Disable Tilt reverse
CAN-Identifier
18EFF753h
18EF53F7h
3.3.8.4 Store parameters
Parameters can be saved with ASCII-command "save" in parameter 1010h, sub-index 1 with a specific key
(similar to CANopen store command). A store command is important for all parameters which are not saved
at access.
Example:
CAN-Identifier
18EFF753h
18EF53F7h
3.3.8.5 Restore default parameters (factory settings)
ASCII command "load" in parameter 1011h, sub-index 1 will restore the device default configuration.
Example:
CAN-Identifier
18EFF753h
18EF53F7h

Address claiming

3.3.9
Two devices with the same address in the same bus network will have the address claiming function exe-
cuted, meaning the new address is being assigned to the device of higher priority while the second device is
being assigned a higher address.
Baumer_GIM700DR_SAEJ1939_EN_V1.00_MNL.docx
27.04.2021
Direction
write to device
received from device
Direction
write to device
received from device
Direction
write to device
received from device
Direction
write to device
received from device
RAW data [hex]
23 78 25 00 01 00 00 00
60 78 25 00 00 00 00 00
RAW data [hex]
23 78 25 00 00 00 00 00
60 78 25 00 00 00 00 00
RAW data [hex]
22 10 10 01 73 61 76 65
60 10 10 01 00 00 00 00
RAW data [hex]
22 11 10 01 6C 6F 61 64
60 11 10 01 00 00 00 00
12/16