6.3. Significance of diagnostic data Slave_Diag
Diagnostic data
Station status 1
Stations tatus 2
Stations tatus 3
Diag_Master
Ident_no.
Extended
Diagnosis header
Operating parameter
Alarms
Supported Alarms
Warnings
Supported Warnings
Firmware Version
MAX limit positive
MAX limit negative
Calibration Value X-
high
Calibration Value X-
low
Calibration Value Y-
high
Calibration Value Y-
low
Serial number
Offset X
Offset Y
Preset X
Preset Y
Resolution
Baumer_GNAMG_Profibus_MA_EN
07.18
Octet
Significance
Nr.
1
Status of
1
2
Status of
2
3
3
Not supported
4
Address of the master having parameterized the slave first
Recognition of the device
5 bis
6
Length of the extended diagnosis including diagnosis
7
header byte in case of extended diagnosis
8
According to parameterization
9
At present no alarms are supported.
10
Defining the supported alarms
11
At present no warnings are supported.
12
Defining the supported warnings
13,14
7-8
Firmware version number
15-18
Maximum positive limit range ( 33 / 330 / 3300 / 33000)
19-22
Maximum negative limit range (-33 / -33 / -3300 / -33000)
10-13
23,24
Calibration value X-axis (max)
14-17
25,26
Calibration value X-axis (min)
18-21
27,28
Calibration value Y-axis (max)
22-25
29,30
Calibration value Y-axis (min)
31-34
26-29
Serial number of inclination sensor
35-38
30-33
Programmed offset X-axis
39-42
34-37
Programmed offset Y-axis
43-46
38-41
Programmed preset X-axis
47-50
42-45
Programmed preset Y-axis
51-52
46,47
Presently selected resolution
Parameterization
Configuration
Diagnostic data (Diag.ext. Bit and Diag.stat. bit in case
of alarm and warning signals)
Response monitoring
Freeze or sync mode
Unique for each device type
Defined and reserved by the PNO
11/19
Baumer IVO GmbH & Co. KG
Villingen-Schwenningen, Germany