12 Troubleshooting
Error
The sensor does not
measure
The sensor has
incorrect measuring
values
The sensor does not
reach the accuracy
BA_OADM20x5.doc ANW_81253059
03.07.2017
Possible reason
The receiving beam is covered by
an object / edge / step
No receiving signal (transparent or
highly reflective object)
Mutual optical interferences
between two or more sensors
Strong ambient light.
Semitransparent, transparent or
highly reflective objects
Rough surface
Color edges
Resolution of the A/D converter in
the control unit
Correction
Make sure that no object is in the receiving
field.
Make sure that the laser spot falls on a diffuse
reflecting surface
Make sure that no other light spot is within the
receiving field of the sensor
Prevent ambient light with a shield
Make sure that the laser spot falls on a diffuse
reflecting surface
Possibly use a sensor with laser line
Mount the sensor the correct way
Read the manual of the control unit