Baumer OM70-11112069 매뉴얼

{카테고리_이름} Baumer OM70-11112069에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Baumer OM70-11112069 3 페이지. Distance sensors

Baumer OM70-11112069 매뉴얼
Optoelektronische Sensoren
Photoelectric sensors
Détecteurs opto-électroniques
OM70-11112069
OM70-X0150.HI0720.VI
Distanz-Sensoren
Distance sensors
Détecteurs de mesure de distances
Í?++4eÂÂ*ÂnÎ
IND. CONT. EQ
11112069
Baumer Electric AG · CH-8501 Frauenfeld
Phone +41 (0)52 728 1122 · Fax +41 (0)52 728 1144
Canada
Italy
Baumer Inc.
Baumer Italia S.r.l.
CA-Burlington, ON L7M 4B9
IT-20090 Assago, MI
Phone +1 (1)905 335-8444
Phone +39 (0)2 45 70 60 65
China
Singapore
Baumer (China) Co., Ltd.
Baumer (Singapore) Pte. Ltd.
CN-201612 Shanghai
SG-339412 Singapore
Phone +86 (0)21 6768 7095
Phone +65 6396 4131
Denmark
Sweden
Baumer A/S
Baumer A/S
DK-8210 Aarhus V
SE-56133 Huskvarna
Phone +45 (0)8931 7611
Phone +46 (0)36 13 94 30
France
Switzerland
Baumer SAS
Baumer Electric AG
FR-74250 Fillinges
CH-8501 Frauenfeld
Phone +33 (0)450 392 466
Phone +41 (0)52 728 1313
Germany
United Kingdom
Baumer GmbH
Baumer Ltd.
DE-61169 Friedberg
GB-Watchfield, Swindon, SN6 8TZ
Phone +49 (0)6031 60 07 0
Phone +44 (0)1793 783 839
India
USA
Baumer India Private Limited
Baumer Ltd.
IN-411038 Pune
US-Southington, CT 06489
Phone +91 20 2528 6833/34
Phone +1 (1)860 621-2121
www.baumer.com/worldwide
1/3
Abmessungen
Dimensions
26
M12 x 1
1DD2
• Alle Masse in mm
• All dimensions in mm
• Toutes les dimensions en mm
Technische Daten
Messdistanz Sd
100 ... 500 mm
Messbereich (Breite)
13.2 ... 66 mm
Strahlform
multi-spot
Messfrequenz
340...1540 Hz 2) 3)
Betriebsspannungsbe-
15 ... 28 VDC
reich +Vs
1)
Stromaufnahme max.
150 mA
(ohne Last)
verpolungsfest
ja, Vs zu GND
kurzschlussfest
ja
Fremdlichtsicherheit
< 35 kLux
Arbeitstemperatur
-10 ... +50 °C
Schutzart
IP 67
Bedienungsanleitung und Anleitung für Programmierung über RS485 bitte auf www.baumer.com herunterladen
Please download the operating instructions and instructions for programming via RS485 from www.baumer.com
Veuillez télécharger le mode d'emploi et les instructions de programmation via RS485 à partir du site www.baumer.com
Technische Änderungen vorbehalten
Dimensions
Elektrischer Anschluss
LED
RS 485
push-
4,3
pull
1)
Class 2, UL 1310, see further sides
4,5
2
19
55
* Senderachse
* emitter axis
* axe émetteur
• Vor dem Anschliessen des Sensors die Anlage spannungsfrei schalten.
• Disconnect power before connecting the sensor.
• Mettre l`installation hors tension avant le raccordement du détecteur.
Technical data
measuring distance Sd
measuring range (width)
beam type
measuring frequency
voltage supply range +Vs
current consumption max.
(no load)
reverse polarity protection
short circuit protection
ambient light immunity
operating temperature
protection class
Connection diagram
BN
(2)
+Vs
Z
Z
GN
(3)
analog
BN = Braun/brown/brun
YE
(4)
GN = Grün/green/vert
out
YE = Gelb/yellow/jaune
GY
(5)
alarm
GY = Grau/grey/gris
WH
(1)
Rx/Tx-
WH = Weiss/white/blanc
PK
(6)
Rx/Tx+
PK = Rosa/pink/rose
RD
(8)
RD = Rot/red/rouge
sync in
BU = Blau/blue/bleu
Z
Z
BU
(7)
0V
Données techniques
100 ... 500 mm
Distance de mesure Sd
13.2 ... 66 mm
Plage de mesure (Largeur)
multi-spot
Forme du faisceau
340...1540 Hz 2) 3)
Fréquence de mesure
1)
15 ... 28 VDC
Plage de tension +Vs
150 mA
Consommation max. (sans charge)
yes, Vs to GND
Protégé contre inversion polarité
yes
Protégé contre courts-circuits
< 35 kLux
Insensibilité à la lumière ambiante
-10 ... +50 °C
Température de fonctionnement
IP 67
Classe de protection
Schéma de raccordement
5
4
6
8
7
3
1
2
100 ... 500 mm
13.2 ... 66 mm
multi-spot
340...1540 Hz 2) 3)
1)
15 ... 28 VDC
150 mA
oui, Vs vers GND
oui
< 35 kLux
-10 ... +50 °C
IP 67