Baumer AMG 11 D29 매뉴얼 - 페이지 15

{카테고리_이름} Baumer AMG 11 D29에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Baumer AMG 11 D29 15 페이지. Absolute encoder with devicenet

9.2

Display elements (status display)

A DUO LED (green/red) is located in the bus cover which works in accordance with DeviceNet specification
in the combined module/network status and supplies information about the status of the encoder and the
network.
LED status
Status
Off
Not connected
Green flashing
Device active and online
No connections set up
Green
Device active and online
Connections are set up
Red
Critical device error critical
communication error
Red flashing
Repairable error

BUDE_Manual_DeviceNet_EN.doc

MB704.E – 10A1 – Firmware version 1.01
22.10.2010 / bja
Description
No power supply
- Dupl. MAC-ID Check not finished.
- Power supply not connected
-
The device is working under normal conditions and
is online, but no connection has been set up.
- The encoder has not yet been configured by the
master
- Configuration not complete or faulty
-
The device is working under normal conditions and
is online, connections in "set up" status"
The device is an irreparable error status
- No network communication possible
- User address has been assigned twice (MAC-ID)
-
I/O connections are in time-out status
15/15
P.O. Box 12 69 43 · D-10609 Berlin, Germany
Phone: +49 (0)30/69003-0 · Fax: +49 (0)30/69003-104
[email protected] · www.baumer.com
Baumer Hübner GmbH
Technical modification reserved