6.4.13. Parameter 61000: Name of Station

Read: This parameter is to read out the name of station (encoder name). Name length is from zero
(deleted) on to 240 characters. No zero termination.
Parameter
Type
Data type
Value range:
Data: 61000 [0]
61000 [n]

6.4.14. Parameter 61001: IP of Station

Read: This parameter is to read the IP of station (encoder IP address).
Parameter
Type
Data type
Value range:
Data: 61001[0]

6.4.15. Parameter 61002: MAC of Station

Read: This parameter is to read the encoder's MAC ID.
Parameter
Type
Data type
Value range:
Data: 61002 [0]
61002 [1]
61002 [2]
61002 [3]
61002 [4]
61002 [5]
(*) example only, device-specific

6.4.16. Parameter 61003: Default Gateway of Station

Read: This parameter is to read the Default Gateway IP address.
Parameter
Type
Data type
Value range:
Data: 61003 [0]
Baumer_BUDE-PROFINET_MA_EN.docx
14.06.2016 / bja
61000
Read only
octet string (0x0A)
ASCII
to
mit n+1 = String length name of station
61001
Read only
UINT32 (0x07)
0.0.0.0 to 255. 255. 255. 255.
Encoder IP
61002
Read only
octet string (0x0A)
00:0E:CF:xx:xx:xx
0x00
0x0E
0xCF
0x03
0x20
0x00
61003
Read only
UINT32 (0x07)
0.0.0.0 to 255. 255. 255. 255.
Default-Gateway IP