7.3. Encoder operating parameters
Description of operating parameters
Parameter
Significance
Behaviour of the output code relating to the shaft's sense of rotation when looking at
Sense of rotation
the flange.
CW („clockwise") = ascending values with clockwise rotation
CCW („counter-clockwise") = ascending values with counter-clockwise rotation
Resolution
Number of steps per revolution, input in integral steps
(„Measuring units
per revolution")
Measuring range
Total resolution = number of steps per revolution x number of revolutions,
(„Total Measuring
input in integral steps
Range")
Steps
The actual encoder position is assigned to a certain position value (referencing)
Operating parameter values
Parameter
Value range
Sense of rotation
CW/CCW
1 to 4096 – magtivo
Resolution
1 to 8192 – multivo
1 to 262144 – multivoPlus
Measuring range
1 to 67108864 (2
1 to 536870912 (2
1 to 2147483648 (2
Peset value
0 to (measuring range - 1 step)
Manual_ProfibusDPV2_BIDE_EN.docx
22.11.12
Default setting
CW
4096
8192
262144
26
) – magtivo
67108864
29
) – multivo
536870912
31
) – multivoPlus
2147483648
0