MOUNTING / MOUNTING TO DRIVE SHAFT
)
4.3.3
Version with through hollow shaft
Lifetime restrictions and angle error by radial deviations
High runout of the drive shaft can cause encoder angle error, see
page
High runout of the drive shaft can cause vibrations, which can shorten the lifeti-
me of the encoder�
» Lubricate drive shaft!
» Minimize drive shaft runout (≤0.2 mm; ≤0.03 mm recommended).
>113 mm
i
The encoder must be mounted with cable connection facing downward and not
exposed to water�
10/32
12�
ød (mm)
16
h6
20
h6
10b
10c
Loosen the screw
8b
10a
5
10c
10e
10b
10d
1�6x8 mm
Tighten the screw
Mt = 2-3 Nm
MB244EN - 11171691, 16A3, Baumer_HMG10-SSI_II_EN
section 4.5,
TX 10
8c
9
10b
10c
10 mm