Baumer HMG 11 설치 및 작동 지침 - 페이지 44
{카테고리_이름} Baumer HMG 11에 대한 설치 및 작동 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. Baumer HMG 11 48 페이지. Absolute encoder through hollow shaft
9
Technical data
9
Technical data
9.1
Technical data - electrical ratings
• Voltage supply:
• Consumption w/o load:
• Initializing time:
• Interfaces:
• Function:
• Transmission rate:
• Profile conformity:
• Device adress:
• Steps per turn:
• Number of turns:
• Additional output signals:
• Sensing method:
• Code:
• Code sequence:
• Inputs:
• Interference immunity:
• Emitted interference:
• Programmable parameters:
• Diagnostic function:
• Status indicator:
• Approvals:
41
9...30 VDC
≤100 mA (per interface SSI)
≤250 mA (per interface bus)
≤200 ms after power on
SSI, Profibus-DPV0, CANopen®, DeviceNet
Multiturn
9.6...12000 kBaud (Profibus)
10...1000 kBaud (CANopen®)
125...500 kBaud (DeviceNet)
Profibus-DPV0
CANopen® CiA DSP 406 V 3.0
Device Profile Encoder V 1.0
Rotary switch in bus cover
8192 / 13 bit
≤65536 / 16 bit
Square-wave TTL (RS422)
Square-wave HTL
Optical
Gray (version SSI)
CW default
SSI clock (version SSI)
EN 61000-6-2
EN 61000-6-3
Depending on the selected absolute interface
Position or parameter error
DUO-LED integrated in bus cover
CE, UL approval / E256710
Baumer_HMG11-A-T1_II_DE-EN (19A1)
MB097aT1 - 11064773