Baumer HMG11 N29 매뉴얼 - 페이지 36

{카테고리_이름} Baumer HMG11 N29에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Baumer HMG11 N29 41 페이지. Absolute encoders with profinet interface

Baumer HMG11 N29 매뉴얼

6.4.13. Parameter 61000: Name of Station

Read: This parameter is to read out the name of station (encoder name). Name length is from zero
(deleted) on to 240 characters. No zero termination.
Parameter
Type
Data type
Value range:
Data: 61000 [0]
61000 [n]

6.4.14. Parameter 61001: IP of Station

Read: This parameter is to read the IP of station (encoder IP address).
Parameter
Type
Data type
Value range:
Data: 61001[0]

6.4.15. Parameter 61002: MAC of Station

Read: This parameter is to read the encoder's MAC ID.
Parameter
Type
Data type
Value range:
Data: 61002 [0]
61002 [1]
61002 [2]
61002 [3]
61002 [4]
61002 [5]
(*) example only, device-specific

6.4.16. Parameter 61003: Default Gateway of Station

Read: This parameter is to read the Default Gateway IP address.
Parameter
Type
Data type
Value range:
Data: 61003 [0]
Baumer_BUDE-PROFINET_MA_EN.docx
14.06.2016 / bja
61000
Read only
octet string (0x0A)
ASCII
to
mit n+1 = String length name of station
61001
Read only
UINT32 (0x07)
0.0.0.0 to 255. 255. 255. 255.
Encoder IP
61002
Read only
octet string (0x0A)
00:0E:CF:xx:xx:xx
0x00
0x0E
0xCF
0x03
0x20
0x00
61003
Read only
UINT32 (0x07)
0.0.0.0 to 255. 255. 255. 255.
Default-Gateway IP
OUI (Organizationally Unique Identifier)
(*) Individual part of MAC
(*)
(*)
36/41
www.baumer.com