Baumer HOG 10 G 설치 및 작동 지침 - 페이지 33
{카테고리_이름} Baumer HOG 10 G에 대한 설치 및 작동 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. Baumer HOG 10 G 36 페이지. Incremental encoder (twin encoder)
Baumer HOG 10 G에 대해서도 마찬가지입니다: 설치 및 운영 지침 매뉴얼 (36 페이지), 설치 및 작동 지침 (40 페이지), 설치 및 운영 지침 매뉴얼 (40 페이지), 설치 및 작동 지침 (32 페이지), 설치 및 작동 지침 (36 페이지)
9
Technical data
9.1
Technical data - electrical ratings
• Voltage supply:
• Consumption w/o load:
• Pulses per revolution:
• Phase shift:
• Scan ratio:
• Reference signal:
• Sensing method:
• Output frequency:
• Output signals:
• Output stages:
• Interference immunity:
• Emitted interference:
• Approvals:
9.2
Technical data - mechanical design
• Size (flange):
• Shaft type:
• Admitted shaft load:
• Protection DIN EN 60529:
• Operating speed:
• Operating torque typ.:
• Rotor moment of inertia:
• Materials:
• Operating temperature:
• Resistance:
• Corrosion protection:
• Explosion protection:
• Connection:
• Weight approx.:
The voltage supply is 9...26 VDC at TTL - version R for versions <95 pulses per revolution
10)
MB136T1 - 11145664
9...30 VDC
5 VDC ±5 % (TTL)
≤100 mA
300...5000 (as ordered)
90° ±20°
40...60 %
Zero pulse, width 90°
Optical
≤120 kHz, ≤300 kHz option
K1, K2, K0 + inverted
HTL-P (power linedriver)
TTL/RS422
(as ordered)
EN 61000-6-2
EN 61000-6-3
CE, UL approval / E217823
ø105 mm
ø16...20 mm (blind hollow shaft)
ø17 mm (cone shaft 1:10)
≤450 N axial
≤600 N radial
IP66
≤6000 rpm (mechanical)
6 Ncm
340 gcm
Housing: aluminium die-cast
Shaft: stainless steel
-40...+100 °C
-25...+100 °C (>3072 pulses per revolution)
Restricted in potentially explosive environments, see section 2.
IEC 60068-2-6, Vibration 20 g, 10-2000 Hz
IEC 60068-2-27, Shock 300 g, 6 ms
IEC 60068-2-52 Salt mist
complies to ambient conditions C4
according to ISO 12944-2
II 3 G Ex nA IIC T4 Gc (gas)
II 3 D Ex tc IIIC T135°C Dc (dust)
(only with option ATEX)
Harting connector HAN® 10 A + HAN® 15 D
1.6 kg, 2.9 kg (option G)
Baumer_HOG10-HOG10G-Harting_T1_DE_EN_202011_MI_11145664 (20A2)
(HTL-P, TTL - version R)
10)
2
Technical data
9
30