Baumer HUBNER BERLIN FOG 9 설치 및 작동 지침 - 페이지 29
{카테고리_이름} Baumer HUBNER BERLIN FOG 9에 대한 설치 및 작동 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. Baumer HUBNER BERLIN FOG 9 32 페이지. Incremental encoder
Baumer HUBNER BERLIN FOG 9에 대해서도 마찬가지입니다: 작동 및 설치 지침 (32 페이지)
9
Technical data
9.1
Technical data - electrical ratings
• Voltage supply:
• Consumption w/o load:
• Pulses per revolution:
• Phase shift:
• Duty cycle:
• Reference signal:
• Sensing method:
• Output frequency:
• Output signals:
• Output stages:
• Interference immunity:
• Emitted interference:
• Approvals:
9.2
Technical data - mechanical design
• Size (flange):
• Shaft type:
• Admitted shaft load:
• Flange:
• Protection DIN EN 60529:
• Operating speed:
• Starting torque:
• Rotor moment of inertia:
• Materials:
• Operating temperature:
• Resistance:
• Corrosion protection:
• Explosion protection:
• Connection:
• Weight approx.:
The voltage supply is 9...26 VDC at TTL - version R for versions <95 pulses per revolution
4)
Up to -25 °C for versions >3072 pulses per revolution
5)
MB195 - 11096124
Baumer_FOG9_II_DE-EN (20A1)
9...30 VDC
(HTL-P, TTL - version R)
4)
5 VDC ±5 % (TTL)
≤100 mA
100...5000 (as ordered)
90° ±20°
40...60 %
Zero pulse, width 90°
Optical
≤120 kHz, ≤300 kHz option
K1, K2, K0 + inverted, error output (option EMS)
HTL-P (power linedriver), TTL/RS422 (as ordered)
EN 61000-6-2
EN 61000-6-3
CE, UL approval
ø115 mm
ø10...11 mm solid shaft (as ordered)
≤200 N axial, ≤300 N radial
EURO flange B10
IP66
≤10000 rpm (mechanical)
≤6 Ncm
160 gcm
2
Housing: aluminium die-cast
Shaft: stainless steel
-30
...+100 °C (with flange connector)
5)
-30
...+80 °C (with connecting cable)
5)
Restricted in potentially explosive environments, see section 2.
IEC 60068-2-6
Vibration 10 g, 10-2000 Hz
IEC 60068-2-27
Shock 100 g, 6 ms
IEC 60068-2-52 Salt mist
complies to ambient conditions C4
according to ISO 12944-2
II 3 G Ex nA IIC T4 Gc (gas)
II 3 D Ex tc IIIB T135°C Dc (dust)
Flange connector M23, 12-pin
Mating connector
700 g
Technical data
9
26