Technical data

9.1

Technical data - electrical ratings

• Voltage supply:
• Consumption w/o load:
• Pulses per revolution:
• Phase shift:
• Duty cycle:
• Reference signal:
• Sensing method:
• Output frequency:
• Output signals:
• Output stages:
• Interference immunity:
• Emitted interference:
• Approvals:
9.2

Technical data - mechanical design

• Size (flange):
• Shaft type:
• Shaft loading:
• Flange:
• Protection DIN EN 60529:
• Operating speed:
• Starting torque:
• Rotor moment of inertia:
• Materials:
• Operating temperature:
• Resistance:
• Explosion protection:
• Connection:
• Weight approx.:
*
The voltage supply is 9...26 VDC at TTL - version R for versions <95 pulses per revolution
** Up to -25 °C for versions >3072 pulses per revolution
MB195 - 11096124
Baumer_FOG9_II_DE-EN (16A4)
9...30 VDC* (HTL-P, TTL - version R)
5 VDC ±5 % (TTL)
≤100 mA
100...5000 (As ordered)
90° ±20°
40...60 %
Zero pulse, width 90°
Optical
≤120 kHz
≤300 kHz option
K1, K2, K0 + inverted
Error output (only EMS)
HTL-P (power linedriver)
TTL/RS422
(As ordered)
EN 61000-6-2:2005
EN 61000-6-3:2007/A1:2011
CE, UL approval / E256710
ø115 mm
ø10...11 mm solid shaft (As ordered)
≤200 N axial; ≤300 N radial
EURO flange B10
IP66
≤10000 rpm (mechanical)
≤6 Ncm
160 gcm
2
Housing: aluminium die-cast
Shaft: stainless steel
-30**...+100 °C (Version with flange connector)
-30**...+80 °C (Version with connecting cable)
Restricted in potentially explosive environments, see section 2.
IEC 60068-2-6:2007
Vibration 10 g, 10-2000 Hz
IEC 60068-2-27:2008
Shock 100 g, 6 ms
II 3 G Ex nA IIC T4 Gc (gas)
II 3 D Ex tc IIIB T135°C Dc (dust)
Flange connector M23, 12-pin
Mating connector
700 g
9
Technical data
26