10

Technical data

10.1

Technical data - electrical ratings

• Voltage supply:
• Consumption w/o load:
• Pulses per revolution:
• Phase shift:
• Duty cycle:
• Reference signal:
• Sensing method:
• Output frequency:
• Output signals:
• Output stages:
• Shaft insulation:
• Transmission length:
• Interference immunity:
• Emitted interference:
• Approvals:
HOG 86 M
• Operating principle:
10.2

Technical data - mechanical design

• Size (flange):
• Shaft type:
• Admitted shaft load:
• Drive shaft tolerance:
• Protection EN 60529:
• Operating speed:
• Operating torque:
• Rotor moment of inertia:
• Materials:
• Resistance:
• Corrosion protection:
• Explosion protection:
HOG 86
• Operating temperature:
• Connection:
• Weight approx.:
HOG 86 M
• Operating temperature:
• Connection:
• Weight approx.:
Up to -25 °C for versions >3072 pulses per revolution
12)
MB194 - 11072323
Baumer_HOG86-HOG86M_DE_EN_202208_MI_11072323 (22A1)
9...30 VDC (HTL, TTL - version R)
5 VDC ±5% (TTL)
≤100 mA
500...5000 (as ordered)
90° ±20°
45...55 %, 40...60 % (>3072 pulses per revolution)
Zero pulse, width 90°
Optical
≤170 kHz, ≤300 kHz option
K1, K2, K0 + inverted, error output (option EMS)
HTL-P (power linedriver), TTL/RS422 (as ordered)
2.8 kV
≤350 m at 100 kHz (HTL-P), ≤550 m at 100 kHz (TTL)
EN 61000-6-2
EN 61000-6-3
CE, UL/CSA
Redundant sensing
ø99 mm
ø12...16 mm (blind hollow shaft)
ø17 mm (cone shaft 1:10)
≤350 N axial, ≤450 N radial
0.2 mm radial
IP66
≤10000 rpm (mechanical)
≤6 Ncm
160 gcm
2
Housing: aluminium, shaft: stainless steel
IEC 60068-2-6, Vibration 20 g, 10-2000 Hz
IEC 60068-2-27, Shock 250 g, 6 ms
IEC 60068-2-52 Salt mist complies to
ambient conditions C4 according to ISO 12944-2
II 3 G Ex nA IIC T4 Gc (gas)
II 3 D Ex tc IIIC T135°C Dc (dust)
(only with option ATEX)
-40
...+100°C, -40
12)
12)
Restricted in potentially explosive environments, see section 2.
Terminal box / flange connector M23, 12-pin / cable 1 m
1.3 kg
-40
...+100 °C
12)
Restricted in potentially explosive environments, see section 2.
2x terminal box
1.4 kg
Technical data
...+90 °C (fixed cable)
10
40