5.1.2

Cable connection for version with cable glands

To ensure the speciied protection of the device the correct cable diameter must
be used.
Connecting cables are not in scope of delivery.
TX 20
10
MB247EN - 11171697, 16A2, Baumer_PMG10-ProibusDP_II_EN
11 9
[ A ]
see
section 5.1.4
15
14
13
17 mm
Connecting cable
ø5-9 mm
ELECTRICAL CONNECTION / PROFIBUS DP
12
Cable shield
Mt = 2-3 Nm
Bus connecting box
9
Proibus DP
Torx and slotted screw,
10
M4x32 mm
Washer A4, DIN 137
11
Connector (male)
12
D-SUB
Cable gland
13
M16x1�5 mm
for cable ø5-9 mm
Connecting terminal
14
Connector (female)
15
D-SUB
(Connection to 12)
12/25