Baumer Hubner Berlin PMG 10 Proibus DP 설치 및 운영 지침 매뉴얼 - 페이지 19

{카테고리_이름} Baumer Hubner Berlin PMG 10 Proibus DP에 대한 설치 및 운영 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Baumer Hubner Berlin PMG 10 Proibus DP 28 페이지. Absolute encoder with magnetic sensing

ELECTRICAL CONNECTION / SPEED SWITCH AND ADDITIONAL OUTPUT INCREMENTAL
5.2.3

LED function displays

LED
INC1
INC2
(additional output
incremental)
Status
Speed
5.2.4

Speed switch - Switching characteristics

Event
During initialisation
After initialisation and
speed ≤ -ns (off)
-ns (off) < speed ≤ -ns (on)
-ns (on) < speed < +ns (on)
+ns (on) ≤ speed < +ns (off)
+ns (off) ≤ speed
High resistance
Resistance between
SP+ and SP-
Low resistance
n
+ns (on) = Activation speed at shaft rotation in positive rotating direction*
+ns (off) = Deactivation speed at shaft rotation in positive rotating direction*
-ns (on) = Activation speed at shaft rotation in negative rotating direction*
-ns (off) = Deactivation at shaft rotation in negative rotating direction*
* See
section 6, page 19
MB247EN - 11171697, 16A2, Baumer_PMG10-ProibusDP_II_EN
red
Without function
Undervoltage
Overload
Over-temperature
Internal error
Speed higher switching speed Speed lower switching speed
(overspeed)
-n
-ns (off)
= Speed
State of the speed switch output
High resistance (overspeed)
High resistance (overspeed)
State unchanged
Low resistance (no overspeed) after initialisation
if the encoder is rotating between the switching
range during initialisation.
Low resistance (no overspeed)
State unchanged
Low resistance (no overspeed) after initialisation
if the encoder is rotating between the switching
range during initialisation.
High resistance (overspeed)
-ns (on)
0
green
Without function
OK
OK
+ns (on)
+ns (off)
+n
16/25