Baumer Hubner Berlin PMG 10-SSI 설치 및 운영 지침 매뉴얼 - 페이지 12

{카테고리_이름} Baumer Hubner Berlin PMG 10-SSI에 대한 설치 및 운영 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Baumer Hubner Berlin PMG 10-SSI 28 페이지. Absolute encoder with magnetic sensing

MOUNTING
4.4
Maximum permissible mounting tolerance when the Baumer Hübner K 35 spring
disk coupling is used
Encoders should be driven through the Baumer Hübner K 35 spring disk coupling (acces-
)
sory), that can be pushed onto the shaft without axial loading
The encoder must be mounted on the drive with the least possible angular error
)
and parallel misalignment�
Risk of damaging the ball bearings
Coupling components must not be driven onto the shaft with improper force (e� g�
hammer impacts), because of the risk of damaging the ball bearings�
Admissible
parallel misalignment
* For insulated hub version
All dimensions in millimeters, unless otherwise stated�
9/25
2-10
Admissible
angular error
MB245EN - 11171693, 16A1, Baumer_PMG10-SSI_II_EN
Admissible
axial movement
±0�7 (±0�3*)