10

Technical data

10.1

Technical data - electrical ratings

• Voltage supply:
• Consumption w/o load:
• Pulses per revolution:
• Phase shift:
• Duty cycle:
• Reference signal:
• Sensing method:
• Output frequency:
• Output signals:
• Output stages:
• Interference immunity:
• Emitted interference:
• Approvals:
10.2

Technical data - mechanical design

• Size (flange):
• Shaft type:
• Admitted shaft load:
• Flange:
• Protection EN 60529:
• Operating speed:
• Operating torque typ.:
• Rotor moment of inertia:
• Materials:
• Operating temperature:
• Resistance:
• Corrosion protection:
• Explosion protection:
• Connection:
• Weight approx.:
MB240 - 11155817
Baumer_POG86-G_DE_EN_202210_MI_11155817 (22A2)
9...30 VDC (HTL-P, TTL - version R)
5 VDC ±5 % (TTL)
≤100 mA
500...5000 (as ordered)
90° ±20°
45...55 %, 40...60 % (>3072 pulses per revolution)
Zero pulse, width 90°
Optical
≤120 kHz, ≤300 kHz option
K1, K2, K0 + inverted, error output (option EMS)
HTL-P (power linedriver); TTL/RS422
(as ordered)
EN 61000-6-2
EN 61000-6-3
CE
UL/CSA
ø115 mm
ø11 mm solid shaft
≤250 N axial, ≤350 N radial
EURO flange B10
IP56
≤12000 rpm (mechanical)
2 Ncm
200 gcm
2
Housing: aluminium, coated
Shaft: stainless steel
-40...+100 °C
-25...+100 °C (>3072 pulses per revolution)
Restricted in potentially explosive environments, see section 2.
IEC 60068-2-6
Vibration 10 g, 10-2000 Hz
IEC 60068-2-27
Shock 300 g, 1 ms
IEC 60068-2-52 Salt mist
complies to ambient conditions C4
according to ISO 12944-2
(not for POG 86E)
II 3 G Ex nA IIC T4 Gc (gas)
II 3 D Ex tc IIIB T135°C Dc (dust)
(only with option ATEX)
Terminal box (option G: 2x)
1.4 kg, 2 kg (option G)
10