Baumer HUBNER BERLIN PROFI NET microGen HMG10P 설치 및 작동 지침 - 페이지 13

{카테고리_이름} Baumer HUBNER BERLIN PROFI NET microGen HMG10P에 대한 설치 및 작동 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. Baumer HUBNER BERLIN PROFI NET microGen HMG10P 32 페이지. Incremental encoder with magnetic sensing
Baumer HUBNER BERLIN PROFI NET microGen HMG10P에 대해서도 마찬가지입니다: 설치 및 작동 지침 (40 페이지), 운영 매뉴얼 (44 페이지)

Baumer HUBNER BERLIN PROFI NET microGen HMG10P 설치 및 작동 지침
4.3.3
Through hollow shaft
)
Service life restrictions and angle error by runouts
High runout of the drive shaft can cause device angle error, see
page
High runout of the drive shaft can cause vibrations, which can shorten the ser-
vice life of the device�
» Lubricate drive shaft!
» M inimize drive shaft runout (≤0.2 mm; ≤0.03 mm recommended).
i
The device must be mounted with cable connection facing downward and not
exposed to water�
>113 mm
MB248EN - 11171699, 19A2, Baumer_HMG10-PROFINET_II_EN
12�
ød (mm)
16
h6
20
h6
10b
10c
MOUNTING / MOUNTING TO DRIVE SHAFT
Loosen the screw
8b
5
10a
10c
10e
10b
10d
1�6x8 mm
Tighten the screw
Mt = 2���3 Nm
section 4.5,
TX 10
8c
9
10b
10c
10 mm
10/27