Baumer HUBNER BERLIN PROFI NET microGen HMG10P 설치 및 작동 지침 - 페이지 20
{카테고리_이름} Baumer HUBNER BERLIN PROFI NET microGen HMG10P에 대한 설치 및 작동 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. Baumer HUBNER BERLIN PROFI NET microGen HMG10P 32 페이지. Incremental encoder with magnetic sensing
Baumer HUBNER BERLIN PROFI NET microGen HMG10P에 대해서도 마찬가지입니다: 설치 및 작동 지침 (40 페이지), 운영 매뉴얼 (44 페이지)
ELECTRICAL CONNECTION / TERMINAL BOX [B]
5.2.5
Switching characteristics speed switch (option)
i
The factory setting of the switching speed for the HMG10P is 6000 rpm� The
HMG10 without programming interface is delivered with the individually ordered
fixed switching speed.
Event
During initialisation
After initialisation and
speed ≤ -ns (off)
-ns (off) < speed ≤ -ns (on)
-ns (on) < speed < +ns (on)
+ns (on) ≤ speed < +ns (off)
+ns (off) ≤ speed
High resistance
Resistance between
SP+ and SP-
Low resistance
n
+ns (off) = Switch-off speed at shaft rotation in positive rotating direction*
-ns (off) = Switch-off speed at shaft rotation in negative rotating direction*
Switching hysteresis
+ns (on) = Switch-on speed at shaft rotation in positive rotating direction*
-ns (on) = Switch-on speed at shaft rotation in negative rotating direction*
* See
section 6, page 20
17/27
-n
-ns (off)
= Speed
: 5...100 % (factory setting = 10 % min. 1 Digit)
State of the speed switch output
High resistance (overspeed)
High resistance (overspeed)
State unchanged
Low resistance (no overspeed) after initialisation
if the device is rotating between the switching
range during initialisation�
Low resistance (no overspeed)
State unchanged
Low resistance (no overspeed) after initialisation
if the device is rotating between the switching
range during initialisation�
High resistance (overspeed)
-ns (on)
0
MB248EN - 11171699, 19A2, Baumer_HMG10-PROFINET_II_EN
+ns (on)
+ns (off)
+n