4.

MOUNTING

4.1
Loosen the clamping ring screw
» Loosen the clamping ring screw a little bit�
4.2
Mounting to drive shaft
)
Service life restrictions and angle error by runouts
High runout of the drive shaft can cause device angle error�
High runout of the drive shaft can cause vibrations, which can shorten the service
life of the device�
» Lubricate drive shaft!
» Minimize drive shaft runout (≤0.05 mm; ≤0.03 mm at speed of >10000 rpm).
i
The device must be mounted with cable connection facing downward and not expo-
sed to water�
* See
page 6
or
page 8
MB168T1EN - 11184527, 19A2, Baumer_HMC16-T1_II_EN
MOUNTING / LOOSEN THE CLAMPING RING SCREW
2*
ød1
in mm: 25
, 30
h6
h6
0�1 mm A
A
3*
, 32
, 40
, 45
h6
h6
h6
h6
4* 12*
, 50
, 55
, 60
h6
h6
h6
1*
9/40