6.8.2.5
Output 1 (or 2) „B": TTL + error output TTL level
Flange connector M23, 12-polig, male contacts, counter-clockwise
There is an inverted error signal via pin 7 available� In case of failure it has
an output of 0 V� In failure-free operation pin 7 have a ~5 V (RS422) TTL level
compared to pin 9�
6.8.2.6
Output 1 (or 2) „C": HTL + error output HTL level
Flange connector M23, 12-polig, male contacts, counter-clockwise
There is an inverted error signal via pin 7 available� In case of failure it has an
output of 0 V� In failure-free operation pin 7 have a ~10���30 V HTL level compa-
red to pin 9�
Depending on version
2)
Only for power supply version „A" or „B"
9)
MB168T1EN - 11184527, 19A2, Baumer_HMC16-T1_II_EN
ELECTRICAL CONNECTION / OUTPUTS HMCP16
Pin
Assignment
1
B–
2
dnu
3
dnu / R+
2)
4
dnu / R–
2)
5
A+
6
A–
7
nE (TTL)
8
B+
9
0 V (nE)
10
0 V
11
dnu
12
dnu / +UB
9)
Pin
Assignment
1
B–
2
dnu
3
dnu / R+
2)
4
dnu / R–
2)
5
A+
6
A–
7
nE (HTL)
8
B+
9
0 V (nE)
10
0 V
11
dnu
12
dnu / +UB
9)
(10���30 VDC)
(10���30 VDC)
21/40