Baumer Hubner HMG10 설치 및 작동 지침 - 페이지 20

{카테고리_이름} Baumer Hubner HMG10에 대한 설치 및 작동 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. Baumer Hubner HMG10 40 페이지. Incremental encoder with magnetic sensing

ELECTRICAL CONNECTION / TRIGGER LEVEL
5.3
Trigger level
Trigger level:
High / Low:
Transmission length:
Output frequency
5.4
Programming interface (only HMG10P)
Via connection SA and SB, encoder parameters such as the number of pulses for the in-
cremental outputs 1 and 2 and/or the switch-off and switch-on speeds can be changed and
read out� With the Z-PA�SDL�1 WLAN adapter, available as accessory, see
encoder can be accessed via a web browser�
5.5
LED function displays
LED
INC1 (incremental
output 1)
INC2 (incremental
output 2)
Status
Speed
20/40
TTL/HTL (Vin = Vout)
≥2.5 V / ≤0.5 V (TTL)
≥Ub -3 V / ≤1.5 V (HTL)
≤550 m at 100 kHz (TTL)
≤350 m at 100 kHz (HTL)
≤600 kHz (TTL)
≤350 kHz (HTL)
red
Undervoltage, overload,
over-temperature
Undervoltage, overload,
over-temperature
Internal error
Speed higher
switching speed (overspeed)
MB258EN - 11196411, 21A1, Baumer_HMG10-Inc_EN_202103_MI_11196411
section
6.1, the
green
OK
OK
OK
Speed lower
switching speed