Baumer Hubner PMG10 설치 및 작동 지침 - 페이지 19

{카테고리_이름} Baumer Hubner PMG10에 대한 설치 및 작동 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. Baumer Hubner PMG10 36 페이지. Absolute encoder ssi with magnetic sensing

Baumer Hubner PMG10 설치 및 작동 지침
5.4
Programming interface (only PMG10P)
Encoder parameter like resolution singleturn and/or multiturn (SSI), binary or gray code
(SSI), additional output 1 and 2, switch-off and switch-on speeds can get and set via the
connections SA and SB� With the Z-PA�SDL�1 WLAN adapter, available as accessory, see
section
6.1, it is possible to get access to the encoder via webbrowser�
5.5
LED function displays
LED
INC1 (additional output
incremental 1)
INC2 (additional output
incremental 2)
Status
Speed
MB245EN - 11171693, 19A3, Baumer_PMG10-SSI_II_EN
ELECTRICAL CONNECTION / PROGRAMMING INTERFACE (ONLy PMG10P)
red
Undervoltage, overload,
over-temperature
Undervoltage, overload,
over-temperature
Internal error
Speed higher
switching speed (overspeed)
green
OK
OK
OK
Speed lower
switching speed
16/29